Wetter is better: New microscopy methods improve accuracy of microbial biofilm imaging

Wetter is better
Shewanella cells processed using cryogenic EM methods (left) and traditional techniques (right) have dramatic structural differences in their EPS morphology (arrows).

(PhysOrg.com) -- At a former uranium mill-tailing site in Rifle, Colorado, scientists are studying how microbes interact with minerals and metals to better understand processes that can help remediate the site. Electron microscopy, or EM, provides the resolution needed to study microbial transformation of metals, but there's a catch.

Typically, sample preparation for EM results in samples that are dehydrated, and dehydrating a microbial sample can shrink and distort its shape, or morphology. So scientists at Pacific Northwest National Laboratory and Lawrence Berkeley National Laboratory turned to state-of-the-art EM approaches at the Department of Energy's EMSL to get a "wetter," thus better, understanding of the morphology of metal biotransforming bacteria and their interactions with minerals.

The insights provided by this study are relevant to developing strategies for environmental remediation; in particular, to assess the impact of microbes on intermediate, or pore-scale, transport and biogeochemical processes. Studying these processes requires an understanding of hydrated microbial morphology, such as that of extracellular polymeric substances (EPS).

EPS are a hydrated network of lipids, , and protein complexes commonly found associated with metals and radionuclides. They are also important in biofilm formation, and thus have implications for processes ranging from corrosion to diseases such as . EPS are typically among the most difficult biological structures to study in their native state, posing a major challenge for obtaining accurate EM images.

Using cultures of metal-reducing microorganisms and samples obtained from the U.S. Department of Energy's uranium-contaminated Integrated Field Research Challenge site in Rifle, Colorado, the scientists compared traditional sample preparation methods and techniques at EMSL, which is located at PNNL. Some of the imaging resources offered there range from high-resolution transmission electron microscopy and scanning to a suite of microscopy tools with cryogenic—or freezing—capabilities. EMSL is one of the few places in the U.S., and the only user facility, where such capabilities are currently available.

Their comparison showed that for lab-grown microbial cultures and natural biofilms, cryogenic EM methods yielded largely artifact-free images, with cells and extracellular matrix preserved in their close-to-natural hydrated state, whereas traditional methods caused substantial shrinkage of the highly hydrated—about 95 percent H2O—extracellular matrix. The ability to prepare and examine samples in the close-to-natural state is available to users through the EMSL user proposal process.

More information: Dohnalkova AC, et al. 2011. "Imaging hydrated microbial extracellular polymers: comparative analysis by electron microscopy." Applied Environmental Microbiology 77(4):1254-1262. DOI: 10.1128/AEM.02001-10.

Citation: Wetter is better: New microscopy methods improve accuracy of microbial biofilm imaging (2011, April 26) retrieved 26 April 2024 from https://phys.org/news/2011-04-wetter-microscopy-methods-accuracy-microbial.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.