Fluorescent glass SRMs are new tool for spectroscopy

June 9, 2007

Researchers at the National Institute of Standards and Technology have developed two new calibration tools to help correct and validate the performance of analytic instruments that identify substances based on fluorescence.

Recent years have seen a significant increase in the development and use of fluorescence-based analytic techniques. Researchers can detect, measure and identify unknown substances—potentially including chemical and biological weapons—using spectroscopic techniques. In fluorescence spectroscopy, scientists send a beam of light at a certain wavelength into a sample, exciting electrons in particular analytes or fluorescent labels, which then emit light at longer wavelengths with measurable energy levels.

This resulting spectral signature, recorded by a fluorescence spectrometer, is distinct for different fluorescent compounds. Many of these assays are being used in areas—including clinical diagnostics, environmental monitoring and drug development—where regulatory requirements are strict and may require standards for instrument qualification and method validation.

To meet these needs, NIST has developed two ready-to-use, fluorescent glass Standard Reference Materials (SRMs), about the size of a pack of a gum, whose certified values can be used to correct fluorescence emission spectra for relative intensity. SRM 2940 (“Orange emission”) has certified values for emission wavelengths from 500 to 800 nanometers when excited with light at 412 nm; SRM 2941 (“Green emission”) has certified values for emission wavelengths from 450 to 650 nm when excited with light at 427 nm.

To use SRM 2941 to calibrate a fluorescence spectrometer, for instance, investigators would excite the glass with light at 427 nm and collect the resulting fluorescence emission from 450 nm to 650 nm. Spectral correction factors for the instrument then could be determined by comparing the measured intensity values to the certified values. The fluorescence spectrum of any unknown sample taken on that instrument that emits from 450 nm to 650 nm then could be corrected to yield its true spectral shape.

These standards also are resistant to photodegradation, making them good performance validation standards. Researchers can use them on a day-to-day basis to validate performance by simply measuring their fluorescence intensity under the same conditions, even for fluorescence instruments with non-tunable wavelength selectors, such as filter-based fluorometers and microscopes.

Standard Reference Materials are among the most widely distributed and used products from NIST. The agency prepares, analyzes and distributes more than 1300 different materials that are used throughout the world to check the accuracy of instruments and test procedures.

Source: National Institute of Standards and Technology


print this article email this article download pdf blog this article bookmark this article     Stumble it Digg this share on Facebook retweet share on Reddit add to delicious
Rate this story - 4.5 /5 (6 votes)


June 9, 2007 all stories

Comments: 0

4.5 /5 (6 votes)
  • Stumble this up

  • Digg this

  • share this

  • hide
  • Related Stories

  • New high-throughput screening technique makes probing puzzling proteins possible
    created Mar 29, 2009 | popularity not rated yet | comments 0
  • Physicists boost 'entanglement' of atom pairs
    created Oct 18, 2006 | popularity not rated yet | comments 0
  • Small nanoparticles bring big improvement to medical imaging
    created Nov 18, 2009 | popularity not rated yet | comments 0
  • Imaging study shows HIV particles assembling around its genome
    created Nov 17, 2009 | popularity not rated yet | comments 0
  • Seeing Previously Invisible Molecules for the First Time
    created Oct 23, 2009 | popularity not rated yet | comments 0



  • hide
  • Relevant PhysicsForums posts

  • moment of inertia and friction
    created 10 hours ago
  • two-dimensional collision
    created 13 hours ago
  • The acceleration of mass using light
    created 15 hours ago
  • Badminton
    created 16 hours ago
  • More from Physics Forums - General Physics

Other News

In the Brain, Seven Is A Magic Number

In the Brain, Seven Is A Magic Number

Physics / General Physics

created 19 hours ago | popularity 4.4 / 5 (27) | comments 8

Having a tough time recalling a phone number someone spoke a few minutes ago or forgetting items from a mental grocery list is not a sign of mental decline; in fact, it's natural.


Scientists react as they stand in front of a screen at CERN

First atoms reported smashed in Large Hadron Collider (Update)

Physics / General Physics

created 21 hours ago | popularity 4.7 / 5 (25) | comments 14

Two circulating beams on Monday produced the first particle collisions in the world's biggest atom smasher, the Large Hadron Collider (LHC), three days after its restart, scientists announced.


New tool for helping pediatric heart surgery

Physics / General Physics

created 6 hours ago | popularity not rated yet | comments 0

A team of researchers at the University of California, San Diego and Stanford University has developed a way to simulate blood flow on the computer to optimize surgical designs. It is the basis of a new tool that may help ...


Straightening messy correlations with a quantum comb

Straightening messy correlations with a quantum comb

Physics / Quantum Physics

created 21 hours ago | popularity 4.8 / 5 (8) | comments 0

Quantum computing promises ultra-fast communication, computation and more powerful ways to encrypt sensitive information. But trying to use quantum states as carriers of information is an extremely delicate ...


Visual assistance for cosmic blind spots

Visual assistance for cosmic blind spots

Physics / General Physics

created 22 hours ago | popularity 4.3 / 5 (3) | comments 0

A bit of imagination on the part of a measuring instrument wouldn't be a bad thing. It could help to add data from areas where the instrument is unable to measure. However, it must do so constructively. In ...