Microchip-based device can detect rare tumor cells in bloodstream

December 19, 2007
Microchip-based device can detect rare tumor cells in bloodstream

Scanning electron microscope image of a lung cancer cell adhering to an antibody-coated micropost on the CTC-chip. Credit: Massachusetts General Hospital BioMEMS Resource Center

A team of investigators from the Massachusetts General Hospital (MGH) Biomicroelectromechanical Systems (BioMEMS) Resource Center and the MGH Cancer Center has developed a microchip-based device that can isolate, enumerate and analyze circulating tumor cells (CTCs) from a blood sample. CTCs are viable cells from solid tumors carried in the bloodstream at a level of one in a billion cell. Because of their rarity and fragility, it has not been possible to get information from CTCs that could help clinical decision-making, but the new device – called the “CTC-chip,”– has the potential to be an invaluable tool for monitoring and guiding cancer treatment.

“This use of nanofluidics to find such rare cells is revolutionary, the first application of this technology to a broad, clinically important problem,” says Daniel Haber, MD, director of the MGH Cancer Center and a co-author of the report in the December 20 issue of Nature. “While much work remains to be done, this approach raises the possibility of rapidly and noninvasively monitoring tumor response to treatment, allowing changes if the treatment is not effective, and the potential of early detection screening in people at increased risk for cancer.”

The existence of CTCs has been known since the mid-19th century, but since they are so hard to find, it has not been possible to adequately investigate their biology and significance. Microchip-based technologies have the ability to accurately sense and sort specific types of cells, but have only been used with microliter-sized fluid samples, the amount of blood in a fingerprick. Since CTCs are so rare, detecting them in useful quantities requires analyzing samples that are 1,000 to 10,000 times larger.

To meet that challenge the MGH BioMEMS Resource Center research team – led by Mehmet Toner, PhD, senior author of the Nature report and director of the center in the MGH Department of Surgery, and Ronald Tompkins, MD, ScD, chief of the MGH Burns Unit and a co-author – first investigated the factors required for microchip analysis of sufficiently large blood samples. The device they developed utilizes a business-card-sized silicon chip, covered with almost 80,000 microscopic posts coated with an antibody to a protein expressed on most solid tumors. The researchers also needed to calculate the correct speed and force with which the blood sample should pass through the chip to allow CTCs to adhere to the microposts.

“We developed a counterintuitive approach, using a tiny chip with critical geometric features smaller than a human hair to process large volumes of blood in a very gentle and uniform manner – almost like putting a ‘hose’ through a microchip,” explains Toner.

Several tests utilizing cells from various types of tumors verified that CTCs were captured by posts covered with the antibody ‘glue.’ Even tumor cells expressing low levels of the target protein and samples containing especially low levels of CTCs were successfully analyzed by the CTC-chip. In contrast to current technology for detecting CTCs, the new microchip device does not require any pre-processing of blood samples, which could damage or destroy the fragile CTCs.

The researchers then tested the CTC-chip against blood samples from 68 patients with five different types of tumors – lung, prostate, breast, pancreatic and colorectal. A total of 116 samples were tested, and CTCs were identified in all but one sample, giving the test a sensitivity rating of 99 percent. No CTCs were found in samples from cancer-free control volunteers. To evaluate the device’s ability to monitor response to treatment, blood samples were taken from nine cancer patients during their treatment for lung, colorectal, pancreatic or esophageal tumors. Changes in levels of CTCs accurately reflected changes in tumor size as measured by standard CT scans.

“We looked at four major cancer killers and were able to consistently find these cells and correlate test results with traditional monitoring techniques,” Toner says. “Some of these tumors have several potential drugs to choose from, and the ability to monitor therapeutic response in real time with this device – which has an exquisite sensitivity to CTCs – could rapidly signal whether a treatment is working or if another option should be tried.”

CTCs also can provide the molecular information needed to identify tumors that are candidates for the new targeted therapies and should help researchers better understand the biology of cancer cells and the mechanisms of metastasis. Considerable work needs to be done before the CTC-chip is ready to be put to clinical use, and the MGH investigators are establishing a Center of Excellence in CTC Technologies to further explore the potential of the device, which also has been licensed to a biotechnology company for commercial development.

Source: Massachusetts General Hospital

4.7 /5 (19 votes)  

Rank 4.7 /5 (19 votes)
Tags

Relevant PhysicsForums posts
  • Can I forget a language?
    created2 hours ago
  • Is Everyday Technology Killing Us?
    createdFeb 08, 2012
  • Exercise and weight loss
    createdFeb 08, 2012
  • Why do we have head aches? Our brains can't feel anything.
    createdFeb 07, 2012
  • "The end of diseases" by David Agus, interview from Daily Show with Jon Stewart
    createdFeb 04, 2012
  • Oncolytic adenovirus
    createdFeb 04, 2012
  • More from Physics Forums - Medical Sciences

More news stories

Researchers develop new method for creating tissue engineering scaffolds

Researchers at Northwestern University have developed a new method for creating scaffolds for tissue engineering applications, providing an alternative that is more flexible and less time-intensive than current technology.

Medicine & Health / Research

created 38 minutes ago | popularity not rated yet | comments 0 | with audio podcast

Drug halts organ damage in inflammatory genetic disorder

A new study shows that Kineret (anakinra), a medication approved for the treatment of rheumatoid arthritis, is effective in stopping the progression of organ damage in people with neonatal-onset multisystem inflammatory disease ...

Medicine & Health / Medications

created 49 minutes ago | popularity not rated yet | comments 0

Molecular profiling reveals differences between primary and recurrent ovarian cancers

There is a need to analyze tumor specimens at the time of ovarian cancer recurrence, according to a new study published in Molecular Cancer Therapeutics. Researchers used a diagnostic technology called molecular profiling to examine ...

Medicine & Health / Cancer

created 38 minutes ago | popularity not rated yet | comments 0 | with audio podcast

Health experts, scientists to discuss bird flu studies

The World Health Organization said Friday it will meet next week to determine whether scientists can publish research on a bird flu virus that may be easily passed among humans.

Medicine & Health / Diseases

created 14 minutes ago | popularity not rated yet | comments 0

Cochlear implants may be safe, effective for organ transplant patients

Cochlear implants may be a safe, effective option for some organ transplant patients who've lost their hearing as an unfortunate consequence of their transplant-related drug regime, researchers report.

Medicine & Health / Other

created 47 minutes ago | popularity not rated yet | comments 0 | with audio podcast


Hovering not hard if you're top-heavy, researchers find

Top-heavy structures are more likely to maintain their balance while hovering in the air than are those that bear a lower center of gravity, researchers at New York University's Courant Institute of Mathematical Sciences ...

Grass to gas: Researchers' genome map speeds biofuel development

Researchers at the University of Georgia have taken a major step in the ongoing effort to find sources of cleaner, renewable energy by mapping the genomes of two originator cells of Miscanthus x giganteus, a large perenn ...

C-sections linked to breathing problems in preterm infants

Research conducted at Yale School of Medicine shows that a cesarean (C-section) delivery, which was thought to be harmless, is associated with breathing problems in preterm babies who are small for gestational age.

Review: Netflix and Hulu's new scripted originals

Within just over a week, Netflix and Hulu are both debuting their first stabs at original scripted programming.

India probes Google over 'forex transactions'

Indian authorities are probing whether online giant Google broke domestic foreign-exchange transactions rules while shifting funds abroad, the Press Trust of India reported on Friday.

Germany freezes signing of disputed Internet pact

Germany on Friday halted the signing of a controversial international accord billed as a way to beat online piracy that has sparked angry protests, saying it needed more time to consider it.